MODEL
|
PROBLEM
|
PROCEDURE
|
Model
1015 |
won't
turn on
|
Check
input voltage 10 to 16 volts dc. Must be negative ground system.
Check keypad make sure no damage to keys. |
Model
1015 |
won't
zero /
shows err
|
Disconnect
weigh bars,rezero unit. Hook one bar up and rezero unit. Do this
until bad bar appears. |
Model
1015 |
stuck
on #
|
Check
keypad for damaged area. make sure unit is in "gross" mode. Disconnect
bars. |
Model
1015 |
scale
isn't
weighing right
|
Check
bars. Make sure they are showing the same. Check code number in
unit. |
Model
1015 |
shows
last
ingredient of reciepe
|
Needs
atleast rev. e if not sent in. Do master reset. Need all info. Before
doing master reset. |
Model
600 |
won't
turn on
|
Check
input voltage 10 to 16 volts dc. Must be negative ground system.
Check keypad make sure no damage to keys. |
Model
600 |
|
Disconnect
weigh bars,rezero unit. Hook one bar up and rezero unit. Do this
until bad bar appears. |
Model
600 |
scale
isn't
weighing right
|
Check
bars. Make sure they are showing the same. Check code number in
unit. |
Model
615 |
won't
turn on
|
Check
input voltage 10 to 16 volts DC. Must be negative ground system.
Check keypad make sure no damage to keys. |
Model
615 |
won't
zero /
shows err
|
4
bar indicators= with one bar hooked up the applied weight will show
up as 4 times the weight on display.50 x 4 =200 |
Model
615 |
locked
on zero
|
4
bar indicators= with two bars hooked up the applied weight will
show up as 2 times the weight on display. |
Model
615 |
scale
isn't
weighing right
|
3
bar units = with one bar hooked up the applied weight will show
up as 2 times the weight on the display.
50 x 2 =100 |
Model
615 |
hooking
up
to rd-4000 / 6000
|
The
RD needs software version 8.0 to run on farm units. |
Model
700 |
won't
turn on
|
Check
input voltage 10 to 16 volts DC. Must be negative ground system.
Check keypad make sure no damage to keys. |
Model
700 |
won't
zero / shows err / stuck on #
|
Disconnect
weigh bars,rezero unit. Hook one bar up and rezero unit. Do this
until bad bar appears. |
Model
700 |
scale
isn't weighing right
|
Check
bars. Make sure they are showing the same. Check code number in
unit. |
Model
700e |
won't
turn on
|
Check
input voltage 10 to 16 volts DC. Must be negative ground system.
Check keypad make sure no damage to keys. |
Model
700e |
won't
zero /
shows err /
stuck on #
|
Disconnect
weigh bars, rezero unit. Hook one bar up and rezero unit. Do this
until bad bar appears. |
Model
700e |
scale
isn't
weighing right
|
Check
bars. Make sure they are showing the same. Check code number in
unit. |
Model
700e |
hooked
up to rd-712
|
Needs
the green wire removed in the rd-712 to work correctly. |
Model
715 |
won't
turn on
|
Check
input voltage 10 to 16 volts DC. Must be negative ground system.
Check keypad make sure no damage to keys. |
Model
715 |
won't
zero /
shows err /
stuck on #
|
Disconnect
weigh bars, rezero unit. Hook one bar up and rezero unit. Do this
until bad bar appears. |
Model
715 |
scale
isn't weighing right
|
Check
bars. Make sure they are showing the same. Check code number in
unit. |
Model
915 |
won't
turn on
|
Check
power supply. vr2 |
Model
915 |
won't
zero /
shows err /
stuck on #
|
Disconnect
weigh bars, rezero unit. Hook one bar up and rezero unit. Do this
until bad bar appears. |
Model
915 |
scale
is not
weighing
right
|
Check
bars. Make sure they are showing the same. Check code number in
unit. |
Model
815 |
scale
is locked up
|
Check
power supply voltages +8,-8,5 volts.Try using course zero pot without
bars hooked up. |
4-pin
bars |
b-c=240
/ c-d=240 / b-d=480
|
a=shield
b= red c=black d=white. |
5-pin
bars |
a-c=350
/ b-d=350 / a-b=262 / b-c=262 / c-d=262 / a-d=262
|
A=red
/ b=green / c=white / d=black / e=shield |
7-pin |
a
=red / b=green / c=white / d=black / e=blue / f=yellow / g=shield
|
|