MODEL PROBLEM
PROCEDURE
Model 1015 won't turn on Check input voltage 10 to 16 volts dc. Must be negative ground system. Check keypad make sure no damage to keys.
Model 1015 won't zero /
shows err
Disconnect weigh bars,rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 1015
stuck on #
Check keypad for damaged area. make sure unit is in "gross" mode. Disconnect bars.
Model 1015
scale isn't
weighing right
Check bars. Make sure they are showing the same. Check code number in unit.
Model 1015
shows last
ingredient of reciepe
Needs atleast rev. e if not sent in. Do master reset. Need all info. Before doing master reset.
Model 600
won't turn on
Check input voltage 10 to 16 volts dc. Must be negative ground system. Check keypad make sure no damage to keys.
Model 600

won't zero /
shows err

Disconnect weigh bars,rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 600 scale isn't
weighing right
Check bars. Make sure they are showing the same. Check code number in unit.
Model 615 won't turn on Check input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.
Model 615
won't zero /
shows err
4 bar indicators= with one bar hooked up the applied weight will show up as 4 times the weight on display.50 x 4 =200
Model 615
locked on zero
4 bar indicators= with two bars hooked up the applied weight will show up as 2 times the weight on display.
Model 615
scale isn't
weighing right
3 bar units = with one bar hooked up the applied weight will show up as 2 times the weight on the display.
50 x 2 =100
Model 615
hooking up
to rd-4000 / 6000
The RD needs software version 8.0 to run on farm units.
Model 700
won't turn on
Check input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.
Model 700
won't zero / shows err / stuck on #
Disconnect weigh bars,rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 700
scale isn't weighing right
Check bars. Make sure they are showing the same. Check code number in unit.
Model 700e won't turn on Check input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.
Model 700e won't zero /
shows err /
stuck on #
Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 700e scale isn't
weighing right
Check bars. Make sure they are showing the same. Check code number in unit.
Model 700e
hooked up to rd-712
Needs the green wire removed in the rd-712 to work correctly.
Model 715
won't turn on
Check input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.
Model 715
won't zero /
shows err /
stuck on #
Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 715
scale isn't weighing right
Check bars. Make sure they are showing the same. Check code number in unit.
Model 915
won't turn on
Check power supply. vr2
Model 915

won't zero /
shows err /
stuck on #

Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 915

scale is not
weighing right

Check bars. Make sure they are showing the same. Check code number in unit.
Model 815
scale is locked up
Check power supply voltages +8,-8,5 volts.Try using course zero pot without bars hooked up.
4-pin bars
b-c=240 / c-d=240 / b-d=480
a=shield b= red c=black d=white.
5-pin bars
a-c=350 / b-d=350 / a-b=262 / b-c=262 / c-d=262 / a-d=262
A=red / b=green / c=white / d=black / e=shield